Case Study of HT Reactor failure? A Resonance Phenomenon in 11KV Water Pumping Station

ABSTRACT

A booster pumping station (BPS) in South India with high power HT pumping motors reported sudden failures due to flashover of the current limiting reactors of the PF correction capacitor circuit. The pumping circuit has its own power factor correction capacitor circuits. The failures were reported repeatedly over three/ four days during December 2009. Extensive re?look on design aspects and simulations studies pointed out no major design issues. Finally it was concluded that the failures were due to the inherent design and workmanship limitations of the reactors itself to handle transient over currents during switching. To find out the specific reasons for such failures (which happened after three to four years’ of working), it was decided to undertake power quality studies. With the long duration of logging at identified points it was noted that at certain random periods , the voltage and current total harmonic distortions increases abnormally high. It was also noted that the predominant harmonic content was the 13th. Detailed investigations provided the reason for such random failures due to the resonance situation in the Pf compensation LC circuit which resonates at 13th harmonic.This has lead to shunt resonance situation for the LC circuit resulting into the failure of the reactor. Larger sized current limiting reactors were found to be the best and economical solution in this case.

DOWNLOAD RESOURCES

CS31-ENGG-2012-Case-Study-of-Ht-Reactor-Failure.pdf

Related POST

Keeping High Speed, Metro Rail Safety and Performance on Track Good Power Quality is the Driver

Metro Rails are all set to take the center stage of mass urban transportation in India's fastest-gro..

Read more

Importance of Power Quality in 21st Century Grid Modernization

Technology is changing, the energy industry is changing, and today's energy customer is changing. Th..

Read more

Seminar on Electrical Utility Management

Issues like Electrical Safety , Power Quality, and Reliability are becoming a priority among Electri..

Read more

Seem National Technical Series On Back Your Pat With Sound Energy Audit

You are invited to register for our next phase of National Technical Series on Back your PAT with Qu..

Read more

Integrated Earthing Systems (Earthing Grid)

Businesses and governments will continue to focus on efficiency and quality improvements while at th..

Read more

PLCs Tripping - A Case Study of identification of voltage Disturbance, and solution

The electronic equipments such as PLCs and digital processors are sensitive to power quality related..

Read more

1st Webinar Business Case For Power Quality Investments By Indian Power Distribution Utilities

17 June, 2014 (Thursday) - Loss reduction, one of the foremost Business performance metrics, drive..

Read more

14th Webinar - Business case for Loss Reduction using advanced Volt-VAR control in Indian grid

22nd February, 2018 (Thursday) - India's power grid system is massive and needs re-balancing to deal..

Read more
Drop us a message

You're in the right place! Just drop us a message. How can we help?

Or see contact page
There seems to be some problem with validating your request. Please try again.
Thank You! Your message has been delivered.